"CP-2016 (Central Processor AK3 1 microprocessor and up to 4 com-munication interfaces)
Detailed Technical Specification and Standards required
Siemens, 7MF4633-1EY22-2AB7-Z, A40-Y01-Y15-Y22 + 7MF4912-3AA02
Technical Data:
SITRANS P DS III, Vn: DC 10.5 - 45 V, HART, 4-20 mA ; Level transmitter; Measuring cell filling: silicone oil; Measuring cell cleaning: normal; Measuring span 25 to 600 mbar (0.363 to 8.70 psi); Version for diaphragm pressure controller: Remote Seal; Process connection of low-pressure side: Female thread 1/4-18 NPT with flange connection; Mounting thread: 7/16-20 UNF to IEC 61518/DIN EN 61518; Non-wetted parts materials: Process flange screws: Stainless steel; Electrical housing: Die-cast aluminum housing, process; International Version: English plate inscription, setting for pressure unit: bar; Explosion protection: None; Electric connection and cable inlet: cable gland M 20x1.5; Display: Customer specific display; Sealing screw: 1/4-18 NPT, with valve in mat. of process flanges; Measuring range to be set : Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi; Stainless steel tag plate and entry in device variable (measuring point description): Max. 16 characters, specify in plain text: Y15: ...........................................; Setting of pressure indicator in non-pressure units: Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters).
Siemens, 7ML52211BA17-Z
Technical Data:
SITRANS Probe LU ; Level transmitter: Ultrasonic, continuous, non-contact; Enclosure/Cable Inlet: Plastic (PBT) 2 x M20 x 1.5 (includes 1 general purpose cable gland: 7ML1930-1AM); Range / Transducer material: 6 meter (20 ft), PVDF Copolymer; Process Connection: 2" NPT ((Taper), ANSI/ASME B1.20.1); Power: 24VDC Nominal, 30VDC Max.; Communication / Output: 4-20mA, HART; Ambient Temperature: - 40°C to 80°C; Enclosure: NEMA/TYPE 4X, 6, IP67, IP68; Approval: Intrinsically safe, ATEX 1G / IECEx / INMETRO Ex ia IIC T4 Ga, RCM, KCC.
Siemens, 7MF4033-1DA10-2DC6-Z, A02-E56-Y01-Y15
Technical data:
Pressure Transmitter for Gauge Pressure, SITRANS P DS III with HART; Measuring Cell Filling: Silicone Oil; Measuring Cell Cleaning: Normal; Measuring span (minimum - maximum): 0.16 - 16 bar; Wetted Parts Material: Seal Diaphragm: Stainless Steel; Process Connection: Stainless Steel. Process Connection: Female thread ½ - 14 NPT; Non-Wetted Parts Material: Housing made of die-cast materials; Version: International version, English plate inscription, setting for pressure unit: bar; Explosion Protection: With ATEX, Type of protection: Explosion-proof (Ex d); Electrical connection / cable Entry: Screwed Gland ½ - 14 NPT; Display: With visible display (setting: mA); Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: Stainless steel 304; Explosion protection "Explosion-proof" to NEPSI (China); Measuring range to be set: Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi; Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ...........................................; Electrical Rating: 10.5 - 45 VDC, 4 - 20 mA HART.
Siemens, 7MF4033-1EA10-2AB6-Z, A01
Technical data:
Pressure Transmitter for Gauge Pressure, SITRANS P DS III with HART; Measuring Cell Filling: Silicone Oil; Measuring Cell Cleaning: Normal; Measuring span (minimum - maximum): 0.63 - 63 bar; Wetted Parts Material: Seal Diaphragm: Stainless Steel; Process Connection: Stainless Steel.; Process Connection: Female thread ½ - 14 NPT; Non-Wetted Parts Material: Housing made of die-cast materials; Version: International version, English plate inscription, setting for pressure unit: bar; Explosion Protection: None; Electrical connection / cable Entry: Screwed Gland M20 X 1.5; Display: With visible display (setting: mA); Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: steel; Electrical Rating: 10.5 - 45 VDC, 4 - 20 mA HART.
Siemens, 7MF4033-1EA10-2AC6-Z, A02+Y01+Y15
Technical data:
Pressure Transmitter for Gauge Pressure, SITRANS P DS III with HART; Measuring Cell Filling: Silicone Oil; Measuring Cell Cleaning: Normal; Measuring span (minimum - maximum): 0.63 - 63 bar; Wetted Parts Material: Seal Diaphragm: Stainless Steel; Process Connection: Stainless Steel. Process Connection: Female thread ½ - 14 NPT; Non-Wetted Parts Material: Housing made of die-cast materials ; Version: International version, English plate inscription, setting for pressure unit: bar; Explosion Protection: None; Electrical connection / cable Entry: Screwed Gland ½ - 14 NPT; Display: With visible display (setting: mA); Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: Stainless steel 304; Measuring range to be set: Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi; Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ...........................................; Electrical Rating: 10.5 - 45 VDC, 4 - 20 mA HART.
Siemens, 7MF4033-1FA10-2AC6-Z, A02+Y01+Y15
Technical data:
Pressure Transmitter for Gauge Pressure, SITRANS P DS III with HART; Measuring Cell Filling: Silicone Oil; Measuring Cell Cleaning: Normal; Measuring span (minimum - maximum): 1.6 - 160 bar; Wetted Parts Material: Seal Diaphragm: Stainless Steel; Process Connection: Stainless Steel.; Process Connection: Female thread ½ - 14 NPT; Non-Wetted Parts Material: Housing made of die-cast materials; Version: International version, English plate inscription, setting for pressure unit: bar; Explosion Protection: None; Electrical connection / cable Entry: Screwed Gland ½ - 14 NPT; Display: With visible display (setting: mA); Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: Stainless steel 304; Measuring range to be set: Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi; Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ...........................................; Electrical Rating: 10.5 - 45 VDC, 4 - 20 mA HART.
Siemens, 7MF4233-1GA10-2AC6-Z, A02+Y01+Y15
Technical data:
Pressure transmitter for absolute pressure from gauge pressure series, SITRANS P DS III with HART; Measuring Cell Filling: Silicone Oil; Measuring Cell Cleaning: Normal; Measuring span (minimum - maximum): 0.17 - 5 bar a; Wetted Parts Material: Seal Diaphragm: Stainless Steel; Process Connection: Stainless Steel; Process Connection: Female thread ½ - 14 NPT; Non-Wetted Parts Material: Housing made of die-cast materials ; Version: International version, English plate inscription, setting for pressure unit: bar; Explosion Protection: None; Electrical connection / cable Entry: Screwed Gland ½ - 14 NPT; Display: With visible display (setting: mA); Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: Stainless steel 304; Measuring range to be set: Specify in plain text (max. 5 characters): Y01: ... up to ... mbar a, bar a, kPaabs, MPaabs, psi a; Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ...........................................; Electrical Rating: 10.5 - 45 VDC, 4 - 20 mA HART.
Siemens, 7MF4233-1HA10-2AC6-Z, A02+Y01+Y15
Technical data:
Pressure transmitter for absolute pressure from gauge pressure series, SITRANS P DS III with HART; Measuring Cell Filling: Silicone Oil ; Measuring Cell Cleaning: Normal; Measuring span (minimum - maximum): 1 - 30 bar a, Wetted Parts Material: Seal Diaphragm: Stainless Steel; Process Connection: Stainless Steel; Process Connection: Female thread ½ - 14 NPT; Non-Wetted Parts Material: Housing made of die-cast materials; Version: International version, English plate inscription, setting for pressure unit: bar; Explosion Protection: None; Electrical connection / cable Entry: Screwed Gland ½ - 14 NPT; Display: With visible display (setting: mA); Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: Stainless steel 304; Measuring range to be set: Specify in plain text (max. 5 characters): Y01: ... up to ... mbar a, bar a, kPaabs, MPaabs, psi a; Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ...........................................; Electrical Rating: 10.5 - 45 VDC, 4 - 20 mA HART.
Siemens, 7MF4433-1EA22-2AC6-Z, A02+A40+Y01+Y15, PN 160
Technical data:
SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 160; Measuring Cell Filling: Silicone Oil; Measuring Cell Cleaning: Normal; Measuring span (minimum - maximum): 6 - 600 mbar, PN 160; Wetted Parts Material: Stainless steel process flanges; Seal Diaphragm: Stainless Steel; Parts of measuring cell: Stainless Steel. Process Connection: Female thread ¼-18 NPT with flange connection, Sealing screw opposite process connection: Mounting thread 7/16 - 20 UNF to IEC 61518/DIN EN 61518; Non-Wetted Parts Material: Process flanges screw: Stainless steel; Electrical housing: Die-cast materials. Version: International version, English plate inscription, setting for pressure unit: bar; Explosion Protection: None; Electrical connection / cable Entry: Screwed Gland ½ - 14 NPT; Display: With visible display (setting: mA); Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: Stainless steel 304; Sealing screws (2 units): ¼-18 NPT, with valve in mat. of process flanges; Measuring range to be set: Specify in plain text: in case of linear characteristic curve (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi; Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ...........................................; Electrical Rating: 10.5 - 45 VDC, 4 - 20 mA HART.
Siemens, 7NG3136-0AB12-Z, C11+U04+Y01
Technical data:
Type: SITRANS TF - transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA; Integrated transmitter: SITRANS TH300, communication capability according to HART V 5.9, Without Ex-protection; Enclosure: Die-cast aluminium; Connections/cable inlet: Screwed glands M20 X 1.5; Digital indicator: With; Mounting bracket and securing parts: made of steel; Test protocol (5 measuring points); Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... to ... °C, °F; Pt100 (IEC) 4-wire; Supply: 13.1 - 35 VDC ; Ambient temperature: -40°C to +85°C.
Siemens, 7NG3212-0NN00, C11+U04+Y01
Technical data:
Type: Temperature transmitter SITRANS TH300 for installation in connection head, type B (DIN 43729), two-wire system 4 ... 20 mA, communication capable to HART, with galvanic isolation, without explosion protection With test protocol (5 measuring points); Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... to ... °C, °F; Pt100 (IEC) 4-wire.
Siemens, 7MC7111-6DB21-Z, E00+...
Technical data:
Type: SITRANS TS100, temperature sensors in cable version, universal use, mineral-insulated version, for unfavorable space conditions; Sensor length: 6mm (0.24 inch); Length of sensor element B, effective length U = B - 10: 500 mm (19.68 inch); Sensor: Pt100, vibration-resistant, -50 ... +400 °C (-58 ... +752 °F); Sensor number/Accuracy: Circuit Pt 100: 1 x 4-wire circuit or 2 x 3-wire circuit, Single, increased accuracy (Class 1/Class A); Design of connection side: Flying leads; Explosion protection: Without explosion protection requirements (Europe, Australia, New Zealand).